1. BALANZA ANALITICA
SARTORIUS R160P
Model R 160 P | |
Weighing capacity g | 30/60/162 |
Readability mg | 0.01/0.02/0.05 |
Tare range (by subtraction) g | -162 |
Standard deviation mg | ≤ ±0.02/0.03/0.05 |
Max. linearity mg | ≤ ±0.03/0.05/0.1 |
Stabilization time (typical) s | 5 |
Display update s | 0.2 |
Adaption to ambient conditions and application requirements | by selection of one of 4 optimized filter levels |
Description:
|
Cal-Pak
|
Capacity:
|
500 g
|
Class:
|
Class 1
|
Certification:
|
NVLAP Certificate
|
Material:
|
Material: Highly Polished Alloy 8 Stainless Steel Weights
|
Construction:
|
2 piece construction with adjusting cavity.
|
Dimensions:
|
Call for exact dimensions
|
Weight Set
Configuration: |
500 g, 50 g, 2 g
|
Case:
|
Supplied in rugged polypropylene case with each individual weight in its own high quality polycarbonate case.
|
Part Number:
|
7261-1W
|
Price:
| |
Additional
Information: |
The total capacity of the weight set is 500 g.
|
3. REFRACTOMETRO DIGITAL. RFM 340. Automatic Refractometer
Perfecto estado. Aproveche. Excelente precio.
The instrument encompasses the following scales :
- sugar % (Brix)
- refractive index
- 5 user defined scales where is possible create personalised scales or insert the following scales:
Each scale has varying degrees of
precision, with a maximum of +/- 0,03% for the scale Brix, e +/- 0,00004 for
refractive index.
Temperature compensation available on all scales
from 5°C to 60°C. The instruments have no moving parts - solid state technology.
External power supply unit for safety in location of instrument and prevention of heat built-up in instrument.
Border line quality, is an arbitrary number used to define the "worth" of a reading. This indicates to the user how well defined the borderline is and hence the reliability of the reading
Large reading display for indication of sample measurement
Artificial sapphire prism in stainless steel sample dish.
Wide range of accessories as "flow cells", waterbaths, printers and computer can be connected to the instrument.
The sample presser will improve measurement accuracy and repeatability by:
- Forcing the sample into intimate contact with the prism surface. This is particularly important with viscous, high concentration samples.
- Providing an "enclosed" environment for the sample so minimising contact with the air and limiting evaporation.
- Preventing strong ambient light from affecting the reading quality.
Password system at two levels allowing only authorised staff to
enter the instrument menu.
A delay before reading can be utilised for
the stabilisation of particular samples. Scales
|
|
Resolution
|
|
Accuracy
|
|
Reading time (sec) |